Release Note for Napatech Link™ Inline Software version 2.0.0 for Linux


Release date

2021-09-21


Description

Software package version ntinl_package_3gd-linux-2.0.0.


Notes

The Napatech Link Inline Software 2.0.0 release introduces support for Flow management for these FPGA images:

  • NT100A01:
    • 9553-46-06 (4x10x25G)
    • 9559-46-06 (4x1/10G)
  • NT200A02:
    • 9534-46-06 (8x10G)
    • 9535-46-06 (2x40G)
    • 9536-46-10 (2x100G)

Installation instructions:

To generate a correct ini-file for inline configuration, start the ntservice executable with the following argument:

./ntservice QMEnable=0

When using more than one adapter, the argument(s) must specify the adapter number. For example, if adapter 1 and 2 are used for inline configuration then do as follows:

./ntservice Adapter1.QMEnable=0 Adapter2.QMEnable=0

Once the ini-file has been generated, the additional arguments are no longer necessary.


Operating systems

The following operating systems are supported:

  • Linux 3.0 -> 3.19 (64-bit)
  • Linux 4.0 -> 4.18 (64-bit)
  • Linux 5.0 -> 5.11 (64-bit)

    The software has been qualified on: CentOS 7 and Ubuntu 20.04

Hardware / FPGA images
Hardware FPGA images Description
NT200A02 200-9534-46-06 8x10G, Capture Flow Management (FM1)
200-9535-46-06 2x40G, Capture Flow Management (FM1)
200-9536-46-10 2x100G port speed, Capture Flow Management (FM1)
NT100A01 200-9553-46-06 4x10/25G, Capture Flow Management (FM1)
200-9559-46-06 4x1/10G, Capture Flow Management (FM1)

Supported server architectures

  • Intel x86 64 bit
  • AMD EPYC Gen2 64 bit


Driver version

3.25.3


LibPCAP version

3.19.1


Tools version

3.25.3


ImgCtrl version

3.14.5


Test status

Complete test plan


Documentation

Documentation is not included in this package.


Release note generated at