2021-06-10
This release note applies to driver package ntanl_package_3gd-windows-12.6.5
The Napatech Link™ Capture 12.6.5 software release is resolving an issue related to missing availability of certain Flow functionality in the API.
This release is a maintenance release in the 12.6 series which introduced these features:
The Napatech driver version applies to these operating systems:
Hardware | FPGA images | Description |
---|---|---|
NT20E3-2-PTP | 200-9501-28-08 | 2x10G, Capture Replay (CR1) |
NT40E3-4-PTP | 200-9502-10-07 | 4x10G, Capture Replay, key matcher, line rate Tx | 200-9537-44-11 | 4x10G, Capture (CR1), key matcher, dedup | 200-9538-44-11 | 4x10G, Capture Replay (CR2), line rate Tx, dedup |
NT80E3-2-PTP | 200-9503-28-07 | 2x40G, Capture Replay (CR1) | 200-9519-28-07 | 8x10G, Capture Replay (CR1) |
NT200A01 | 200-9515-20-10 | 2x100G, Capture, key matcher included | 200-9516-20-10 | 2x100G, Capture Replay, key matcher not included | 200-9531-35-25 | 2x10/25G, Capture Replay (CR1) | 200-9512-28-07 | 2x40G, Capture Replay (CR1) | 200-9522-28-07 | 8x10G, Capture Replay (CR1) |
NT40A01-4x1 | 200-9500-28-08 | 4x1G, Capture Replay (CR1) |
NT100E3-1-PTP | 200-9505-28-07 | 1x100G, Capture Replay (CR1) |
NT40A01 | 200-9517-09-08 | 4x10/1G port speed, Socket Load Balancer |
INTEL-A10 | 200-7000-27-02 | 4x10G, Capture Replay (CR1) | 200-7001-27-02 | 1x40G, Capture Replay (CR1) |
NT200A02 | 200-9521-43-11 | 2x100G, Capture Replay (CR1) | 200-9526-43-11 | 2x40G, Capture Replay (CR1) | 200-9532-43-11 | 2x10/25G, Capture Replay (CR1) | 200-9533-43-11 | 8x10G, Capture Replay (CR1) | 200-9534-35-25 | 8x10G, Capture Flow Management (FM1) | 200-9535-28-07 | 2x40G, Capture Flow Management (FM1) | 200-9536-37-00 | 2x100G port speed, Capture Flow Management | 200-9539-23-01 | 8x10G port speed, CPU Socket Load Balancer | 200-9540-23-01 | 2x40G port speed, CPU Socket Load Balancer | 200-9543-44-10 | 2x100G, Capture Test & Measurement (TM1) | 200-9545-44-10 | 2x40G, Capture Test & Measurement (TM1) | 200-9546-44-10 | 2x10/25G, Capture Test & Measurement (TM1) | 200-9549-43-11 | 4x10/25G port speed | 200-9555-43-11 | 2x1/10G, Capture Replay (CR1) |
NT50B01 | 200-9541-35-25 | 2x10/25G, Capture Replay (CR1) |
NT100A01 | 200-9553-35-25 | 4x10/25G, Capture Flow Management (FM1) | 200-9554-44-10 | 4x10/25G, Capture Test & Measurement (TM1) | 200-9559-35-25 | 4x1/10G, Capture Flow Management (FM1) | 200-9560-44-10 | 4x1/10G, Capture Test & Measurement (TM1) |
3.24.3
3.24.3
3.3.0
3.24.3
3.14.2
Complete test plan
Documentation is available in the “Documentation” folder.
2021-06-10